20’ × 8’ × 9’2” ACCOMMODATION CONTAINER WITH 1 PAIR OF FORKLIFT POCKETS

GENERAL:

 The standard container, for various purposes, is suitable for international container transport. It has connections for lifting and fixing or compounding. The container is designed as a light construction consisting of floor and roof frames and corner profiles. The construction enables compounding of individual containers in longitudinal and transverse directions without limits. It also enables compounding of containers in 2 floors in height (ground floor + first floor), or in 3 floors in height for warehousing of these containers (ground floor + 2 floor). The wall paneling of the container are made of light insulation panels and offer superior heat insulation due to their build quality and physical properties.

DIMENSIONS and TARE (ISO Standard 1161):
External length/inner length:
6.058m/ (5.858m)
External width/inner width: 2.438m/ (2.238m)
External height /inner height: 2.791m/ (2.520m)
Tare: 1950 KGS
 

STEEL FRAMEWORK:

Material: 3mm thick Q235A Steel for top framework and corner posts; 4mm thick Q235A Steel for main bottom framework and 3mm thick Q235A Steel for bottom cross beam
Surface working: electric galvanization min 6~8 μm, zinc compatible epoxy ground coat in a thickness of 20~30μm , final zinc compatible vinyl acrylic coat/chlorinated rubber paint in a thickness of 50~70μm
Fittings: 8 corner fittings (dimensions according to ISO standard 1161), rainwater pipe in the roof framework, plate thickness of 10mm excluding top corner fittings of the top kit of each bundle (20mm thickness)
Forklift openings: openings for fork-lift pockets in the floor framework, dim. 80×250mm in a distance of 1200mm
 

FLOOR:

Composition:
-external cladding: flat galvanized steel sheet metal in a thickness of 0.5mm
-insulation filling: non combustible mineral wool in a thickness of 100 mm among steel transverse supports. Mineral wool density: 40 Kg/m3 -steam blockade: PE foil in a thickness of 80μm
– floor cladding: plywood board in a thickness of 20mm lined with PVC flooring sheets of 1.8mm thickness glued and rolled onto the plywood.
Non Combustible Containers shall have 20mm Cement Boards instead of plywood
Permitted loading : 2.50 KN/m2
Coefficient of thermal conductivity: K=0.039 W/mK
R value (Thermal Resistance) = 2.56 m2K/W
 

CEILING:

Composition:
-external cladding: flat galvanized and painted steel sheet metal in a thickness of 0.5mm.
-insulation filling: non combustible mineral wool in a thickness of 100mm among plywood purlins. Mineral wool density: 40 Kg/m3
-steam blockade: PE foil in a thickness of 80μm
-inner cladding: chip wood panel in a thickness of 9 mm with a white laminate; joining of chip wood panels with PVC profiles
Non Combustible Containers shall have Cement Board Cladding and Steel Framing
Water outlet: 4 PVC rainwater downspout pipes, diameter 40mm in corner pillars
Permitted loading: 1.50 KN/m²
Coefficient of thermal conductivity: K=0.039 W/mK
R value (Thermal Resistance) = 2.56 m2K/W
 

Electrical:

Panel width: 1145mm;
Total panel thickness: 70mm.
Five panels fit along the long sides and two panels fit along the short sides of the container and they are fully interchangeable Note: If there are cables preassembled in roof and wall panels, then the panels must be assembled according to the electrical layout
Composition:
-External cladding: galvanized and painted steel sheet metal in a thickness of 0.5mm
-Insulation filling: non combustible mineral wool in a thickness of 50mm in the wood framework. Mineral wool density: 40 Kg/m3
-Inner Cladding: white chipboard panel in a thickness of 9 mm
Non Combustible Containers shall have Cement Board Cladding and Steel Framing
Permitted loading: 1.00 KN/m²
Coefficient of thermal conductivity: k =0.039 W/mK
R value (Thermal Resistance) = 1.54 m2K/W
 

WINDOWS:

Sliding windows: made of PVC, white color, with dimensions 800×1100mm, glazed with double layer glass in a thickness of 5/9/5mm, with “sliding” mechanism (one side fixed and one sliding)
Rolling shutter external PVC rolling shutters

ELECTRICALS:

Standard: according to VDE 100 and CE regulations
Voltage: 220 V, 50 Hz single phase
External connections: CEE-connection plug/socket, 3-pole 32 A, 220V~, mounted on the top frame in upper corners of a shorter side wall
Inner distribution system: BVVB cables of suitable dimensions (6, 2.5, 1.5 mm2), CE marked, flush-mounted. All cables (located on the ceiling and inside wall panels) run into CE certified plastic conduits. Roof cables and panel cables are connected with CE compliant “jacks”. All jack connections are protected inside CE marked and IP44 rated distribution boxes
Protection: protective current switch (40/2E-0,03A), automatic fuses (B-characteristics) of suitable power (10A/1P, 16A/1P)
Earthing: galvanized connector with a steel plate of dimensions 50 x 20mm welded on the bottom frame 10. Fittings: -electric distribution box – 1×40/2E-0.03A (protective current switch), 1×10A & 2×16A (automatic fuses) -double fluorescent lights 2×36W 220V– 2 each – sockets 220 V– 4 each – switches 220 V – 1 each
 

WARRANTY:

Complete – All components have 1 (one) year warranty